AZ-U9-50X25M
UCODE 9 On-Metal RFID Tag, 50 × 25 × 1.26 mm
A 50 × 25 mm on-metal RFID label with UCODE 9, only 1.26 mm thick, built to read when mounted directly on metal.
Validate samples first. Engineer reply within 24 h.
Check suitability for your application
See the sample validation checklist
| SKU | AZ-U9-50X25M |
|---|---|
| Frequency | UHF 860–960 MHz |
| Protocol | EPC Gen2v2 (ISO/IEC 18000-63), RAIN RFID |
| Chip | NXP UCODE 9 |
| Memory | 96-bit EPC (pre-serialization supported), 96-bit TID with a 48-bit unique serial number, no user memory |
| Chip read sensitivity | −24 dBm (vendor reference) Vendor measurement conditions: 2.15 dBi gain antenna; not finished-tag performance |
| Antenna size | 50 × 25 mm |
| Thickness | 1.26 mm |
| Format | On-metal label |
| Read range | up to 5 m (reference) depends on reader, antenna, power and the tagged material |
| Typical applications | Metal assets & IT |
Design and application notes
UCODE 9 On-Metal RFID Tag, 50 × 25 × 1.26 mm is a UHF on-metal RFID label built around the NXP UCODE 9 chip, measuring 50 × 25 × 1.26 mm. A standard inlay stuck directly on steel or aluminium is detuned and usually cannot be read; this label uses a foam spacer to hold the antenna away from the surface while staying only 1.26 mm thick, so it can be mounted directly on metal.
NXP UCODE 9 provides 96-bit EPC (pre-serialization supported), 96-bit TID with a 48-bit unique serial number, no user memory. NXP lists read sensitivity of −24 dBm and write sensitivity of −22 dBm as vendor reference values (Vendor measurement conditions: 2.15 dBi gain antenna; not finished-tag performance). Validate the complete tag with samples on the intended item and reader setup. Datasheet highlights: Self-Adjust auto-tuning, Memory Safeguard data integrity, dynamic backscatter and a pre-serialized 96-bit EPC; works with single-slit antennas.
Reference read range: up to 5 m (reference). Real-world range depends on the reader, antenna, power and the material the tag is attached to, so treat it as a comparison value and confirm it with samples on your own items.
Typical mounting surfaces are IT equipment, tools, metal containers and machine parts. Apply it to a flat, clean metal area; the label is tuned for metal, so on plastic, wood or cardboard a standard UHF inlay is usually the better and cheaper choice.
It ships as a foam-spacer on-metal label; face printing (asset numbers, logos, barcodes), EPC encoding and other sizes are quoted on request. We send samples first so you can test on your own metal parts, and volume orders are produced with our ISO 9001-certified production partner with 100% inline electrical testing.
Specification basis and validation
Vendor documents describe the chip, not finished-tag read range.
Confirm catalog dimensions against the final tag construction. Reference read ranges require sample testing on your item with your reader setup.
Order in the format you need
Confirm the construction and encoding during sampling, then quote the configuration you validated.
On-metal label
Antenna and chip over a foam spacer with adhesive back, for flat metal surfaces.
Printed face
Asset numbers, logos, barcodes or QR codes printed on the face stock.
Pre-encoded
EPC written to your numbering scheme before shipping, locked on request.
Custom
Other sizes or thicknesses assessed and quoted on request, validated with samples.
What should the sample pass before a bulk order?
Agree the actual use conditions and pass criteria before selecting samples. The catalogue supports shortlisting; confirm finished-tag performance and delivery configuration in writing and through sample validation.
-
Test on the finished metal item
Record the metal material, dimensions, curvature, assembly state and mounting position. Fix reader and antenna settings, use the final spacer, face stock and adhesive, and define the intended read zone.
-
Check reads, identity and mounting separately
Check unique identities inside the target zone and unintended reads outside it. Read back the EPC against printed IDs. Inspect lifting edges, adhesion and behavior after relevant handling; record separate acceptance decisions.
-
Record the approved construction and delivery configuration
Record the SKU, sample revision, lot, device settings, results and approver. Confirm final dimensions, materials, printing, encoding, quantity and delivery requirements, and agree which configuration changes require another trial.
Use the test record to save actual conditions and results. English and Chinese worksheets are provided; the agreed reviewer determines acceptance.
Download test recordHow ordering works
- 01
Specify
Share surface, read distance, chip preference and volume. We shortlist tags that fit.
- 02
Sample
Receive sample tags of the shortlisted designs to try in your own setup.
- 03
Validate
Test on your items, readers and printers. We adjust chip, size or format if needed.
- 04
Produce & ship
Volume production with 100% inline electrical test, then export shipping.
Frequently asked questions
Can the AZ-U9-50X25M be printed and encoded?
What read range will I get with the AZ-U9-50X25M?
How do I get samples and a quote for the AZ-U9-50X25M?
Selection guides
-
On-Metal RFID Tags: Construction, Placement and Testing
Choose an on-metal RFID label by mounting surface, available area, thickness and reader workflow. Test the complete structure before approving bulk supply.
-
RFID Read Range: What Changes the Result in Your Site
RFID read range depends on the complete system. Control power, antenna, surface, orientation and reader settings when comparing labels on real objects.
Related designs
Talk to an RFID engineer
Not sure which tag fits your project?
Send the surface, read distance and volume. An engineer replies within 24 hours with a recommendation and a sample plan.
Email us: sales@antenza.com